Altronix AL600ULACM Power SupplyAltronix AL600ULACM converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC or 24VDC Fail Safe and or Fail Secure outputs with a total of 6A continuous supply current. These power outputs can be converted to dry form "C" contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Altronix AL600ULACM converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC or 24VDC Fail-Safe and/or Fail-Secure outputs with a total of 6A continuous supply current. These power outputs can be converted to dry form "C" contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.

  • Input
    • Input 115VAC 60Hz rated @ 3.5A.
      • Power supply input options:
        • a) One (1) common power input for ACM8/ACM8CB and lock power (factory installed).
        • b) Two (2) isolated power inputs - One (1) to power the ACM8/ACM8CB and one (1) for lock accessory power, (external power supply is required). (Current is determined by the power supply connected, not to exceed a maximum of 10A total).
    • Eight (8) Access Control System trigger inputs.
      • Input options:
        • a) Eight (8) normally open (NO) inputs.
        • b) Eight (8) open collector inputs.
        • c) Any combination of the above.
  • Output
    • 12VDC or 24VDC @ 6A supply current.
    • Eight (8) independently controlled outputs.
      • Output options:
        • a) Eight (8) Fail-Safe and/or Fail-Secure power outputs.
        • b) Eight (8) form "C" 5A rated relay outputs
        • c) Any combination of the above.
    • Eight (8) auxiliary power outputs (unswitched)
      • Output ratings:
        • Fuses are rated @ 3.5A.
    • Filtered and electronically regulated outputs (built-in power supply).
    • ACM8 board main fuse is rated at 10A.
  • Supervision
    • AC fail supervision (form "C" contacts).
    • Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
    • Low battery and battery presence supervision (form "C" contact).
  • Features
    • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
      • Fire Alarm disconnect input options:
        • a) Normally open (NO) or normally closed (NC) dry contact input.
        • b) Polarity reversal input from FACP signaling circuit.
    • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC).
    • Short circuit and thermal overload protection.
    • AC fail supervision (form "C" contact).
  • Visual Indicators
    • Red LEDs indicate outputs are triggered (relays energized).
    • Green LED indicates FACP disconnect is triggered.
    • AC input and DC output LED indicators.
  • Battery Backup
    • Built-in charger for sealed lead acid or gel type batteries.
    • Automatic switch over to stand-by battery when AC fails.
    • Zero voltage drop when unitswitches over to battery backup (AC failure condition).
    • Battery fail and battery presence supervision (form "C" contact).
  • Temperature
    • Operating: 0ºC to 49ºC (32ºF to 120ºF).
    • Storage: - 20ºC to 70ºC ( - 4ºF to 158ºF).
    • Relative Humidity 85% +/- 5%.
      • BTU/Hr. (approx.):
        • 12VDC: 37 BTU/Hr.
        • 24VDC: 74 BTU/Hr.

Altronix AL600ULACM Power Supply

Item no : 10453114356
sold recently : Login >>
US$ 218.93
Pay in 4 interest-free payments of $54.73 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 25 - Jun 30

Enjoy 20% off shipping

US$ 218.93

1-11

US$ 197.04

12-35

US$ 153.25

36-59

US$ 131.36

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Drift Skirt
Drift Skirt

US$ 290.00

Min. order: 1 piece

4.2 (166 reviews)

Sold : Login>>

Related Searches