Honeywell 8C-IP0102 C300 I/O Module | New & Original StockHoneywell 8C IP0102 Experion PKS Series 8 The Honeywell 8C IP0102, also cataloged as the 51454362 275 I O Module Assembly, operates as a dedicated hardware component for stable data acquisition and high density signal termination within Experion PKS Series 8 C300 platforms. Hardware Specifications Parameter Specification Model 8C IP0102 Brand Honeywell Origin United States Weight 0. 3 kg Dimensions 22 mm x 124 mm x 126 mm Operating Temp 40 to +70 deg
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Honeywell 8C-IP0102 Experion PKS Series 8

The Honeywell 8C-IP0102, also cataloged as the 51454362-275 I/O Module Assembly, operates as a dedicated hardware component for stable data acquisition and high-density signal termination within Experion PKS Series 8 C300 platforms.

Hardware Specifications

Parameter Specification
Model 8C-IP0102
Brand Honeywell
Origin United States
Weight 0.3 kg
Dimensions 22 mm x 124 mm x 126 mm
Operating Temp -40 to +70 deg C
Power Consumption Low-power architecture for minimized cabinet heat loading
Hardware Series Experion PKS Series 8 (C300)
Module Function I/O Termination / Module Assembly
Environmental Protection Conformal Coated (CC), G3 Rated (ISA-S71.04-1985)
Corrosion Resistance Resists H2S (Hydrogen Sulfide), Chlorine, and high-humidity ingress
Signal Integrity Integrated Electromagnetic Interference (EMI) shielding
Mounting Vertical DIN-rail installation via compatible Series 8 IOTA

Process Control and DCS Instrumentation

The module assembly features an architecture built to process field data lines directly interfacing with the C300 controller platform. The physical layer integrates comprehensive physical shielding to enforce electromagnetic interference (EMI) suppression across all instrumentation loops, including 4-20 mA HART loop protocol lines. The entire printed circuit board assembly is structurally protected by a factory-applied conformal coating that meets ISA-S71.04-1985 Class G3 standards, providing chemical isolation against airborne pollutants such as Hydrogen Sulfide (H2S) and Chlorine within an operating temperature range of -40 to +70 deg C.

Frequently Asked Questions

Q: What is the technical function of the factory-applied coating on the 8C-IP0102 hardware?

A: The board is built with an industrial conformal coating certified to ISA-S71.04-1985 Class G3 specifications. This protective barrier seals the electronic pathways against conductive dust, ambient moisture, and harsh corrosive gases like Hydrogen Sulfide and Chlorine.

Q: How does this module manage localized thermal signatures inside high-density enclosures?

A: The unit employs a low-power internal component architecture engineered to optimize conversion efficiency. This configuration minimizes baseline heat generation, mitigating cabinet heat loading when modules are installed in multi-slot, high-density configurations.

Q: Is this hardware piece installed directly onto standard enclosure back panels?

A: No, the 8C-IP0102 requires a compatible Series 8 Input/Output Termination Assembly (IOTA) base plate for structural support and data interface routing. The combined IOTA and module sub-assembly is then mounted vertically onto standard 35 mm DIN rails.

Field Installation Guidelines

  • IOTA Alignment and Mechanical Seating: Insert the module assembly squarely onto the alignment guides of the target Series 8 IOTA. Push firmly until the mechanical locking ears click into place to ensure full engagement of the backplane interface pins.
  • Grounding Plane Continuity: Verify that the DIN rail structure is securely bonded to the master copper enclosure ground bar using low-impedance cables to provide a clear path for the built-in EMI shielding circuits.
  • Field Wiring Paths and Segregation: Keep all field terminal input and output signaling conductors isolated within separate wire ducts. Maintain distinct separation from heavy AC grid cables or variable speed drive conductors to prevent cross-talk noise induction.

Honeywell 8C-IP0102 C300 I/O Module | New & Original Stock

Item no : 62610175712
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 1 - Jul 6

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches